-40%

Super Large Caliber Clamp AC Current Meter Tester Range 0.0mA to 3200A

$ 284.59

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Current Range: AC  0.0A~3200A
  • Current Type: Superlarge Caliber Leakage Clamp Meter
  • Line Voltage: Below 600V circuit test
  • Display Mode: 4 digital LCD display,47mm×28.5mm
  • Clamp Size: 148mmx108mm
  • Meter Dimension: 350 mm×180 mm×55 mm
  • Measurement method: Clamp CT,integration method
  • Country/Region of Manufacture: China
  • Working Environment: -10℃~40℃;below 80%rh
  • Max Resolution: AC  0.1A
  • Custom Bundle: No
  • Restocking Fee: No
  • Brand: CNYST
  • MPN: ETCR7100A
  • Sampling Rate: 2 times/second
  • Power Supply: 6V DC
  • Modified Item: No
  • Meter Weight: 1.5 kg
  • Frequency Range: 50Hz、60Hz Automatic Identification
  • Condition: New
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Return shipping will be paid by: Buyer
  • Store Environment: -10℃~60℃;below 70%rh

    Description

    Super Large Caliber Clamp AC Current Meter Tester Range 0.0mA to 3200A
    Introduction
    ETCR7100 Superlarge Caliber Leakage Clamp Meter suitable for measuring AC current, leakage current below 600V, range: 0.0mA~3200A, CT size: 108mmx148mm, can clamp and test Φ108mm cable and flat steel grounding wire. The core is made of magnetic shielding material with strong anti-interference ability, ensures the accuracy and stability of measurement. The meter adopts Non-contact current measurement, safe and simple operation. with the backlight function, make the meausrement clearly visible in dark place.
    The meter with data hold, data storage and other functions, can store 99 groups of data, the instrument connect computer by RS232 interface, stotage data can be uploaded to the computer, easy to read, analysis, save, print and so on.
    specification
    Function
    AC leakage current, large current test (especially suitable for cable leakage current and transformer grounding flat steel leakage current detection)
    Power Supply
    6V DC(LR6×4 alkaline dry batteries, continuous working 12 hours)
    Measurement method
    Clamp CT

    integration method
    Clamp Size
    148mmx108mm( can clamp Φ108mm wire, or 160mm × 4mm grounding flat steel )
    Range
    AC  0.0A

    3200A
    Max Resolution
    AC  0.1A
    Measure Accuracy
    (23℃±3℃, below 70%RH,
    measured wire at the center of the clamp)
    AC 0.0A

    499A       ±2%±5dgt
    AC 500A

    999A      ±3%±5dgt
    AC 1000A

    2999A  ±4%±5dgt
    AC 3000A

    3200A  ±5%±5dgt
    Conductor Position
    The detected conductor is in the center position of the clamp
    Data Storage
    99 Groups , flash display “FULL” symbol indicate storage full
    USB Interface
    With USB interface, storage data can be uploaded to computer, convenient to data analyze
    Communication cable
    USB communication cable, length: 1.8M
    Frequency
    50Hz

    60Hz Automatic Identification
    Shift
    Automatic
    Sampling Rate
    2 times/second
    Line Voltage
    Below 600V circuit test
    Display Mode
    4 digital LCD display

    47mm×28.5mm
    Meter Dimension
    350 mm×180 mm×55 mm
    Backlight
    Yes, Suitable for dark places
    Data Hold
    Data hold function: "HOLD" symbol display
    Overflow Display
    Exceed measure range overflow function: “OL” symbol display
    PEAK Hold
    Press PEAK key to open the peak hold function, press PEAK key once again to cancel this function
    Automatic Shutdown
    5 minutes after power on, it will power off automatically without any operation to reduce the power consumption
    Battery Voltage
    While battery voltage is lower than 5.2V. low battery voltage symbol display, remind to replace the battery
    Meter Weight
    1.5 kg
    Package Weight
    3 kg   (include accessories)
    Working Environment
    -10℃~40℃

    below 80%rh
    Store Environment
    -10℃~60℃

    below 70%rh
    Insulation Strengh
    AC 3700kV/rms(Between iron core and shell)
    Suitable Safety Standard
    IEC1010-1

    IEC1010-2-032

    Pollution 2

    CAT Ⅲ(600V)
    PAYMENT INFORMATION:
    1.We can accept Credit Cards,Paypal,T/T,Escrow and so on.
    2.The buyer is responsible for any tax and/or duty charged by their country.
    INTERNATIONAL SHIPPING:
    The package will be shipped by EUB DHL, FEDEX or EMS. After we shipped the parcel,we'll fill in the tracking number and inform you by e-mail.Please write the correct address and telephone number when you make orders,so the courier can contact you when they deliver the parcel to you. Thanks!
    WARRANTY INFORMATION:
    1.All the products have been checked and packed in good condition before dispatch.
    2.All the products with one year warranty.
    3.If you find any quality problems,please send it back within 3 days,and we'll send you a new one or refund you the payment after we get the returned one.
    4.Buyers have to pay for the return cost and we will pay the cost for resend
    5.All products returned should be in new conditions.